KERBEROS POWER 6000.B

Kerberos POWER 6000.B

basic parameters
  • Recommended boiler volume: 200 - 1000 litres
  • Optional number of power modules: 1 - 3
  • Photovoltaic panel power: one to three separate sections of about 2,5 kWp
  • Recommended heater input for one power module: 2 - 2.5 kW
  • Backup of photovoltaic network heating: NO
  • Utilization of energy surpluses: NO
  • GSM based remote monitoring
TECHNICAL DATA OF ONE POWER MODULE
  • Input open circuit voltage (limits): 200 - 340 V
  • MPP tracking range: 185 - 320 V
  • Maximum current: 10 A
  • Maximum efficiency: 99%
  • Thermal fuse: YES electronic, common to all power modules
  • Mains connection: 230 V / 50 Hz
  • Custom grid consumption < 5 W
  • Ingress protection IP20
     
Documents to download here

 

Warning

Panels are available in various designs on the market, and if the technical requirements are met, it is not necessary to follow the recommended panel performance. The maximum idle input voltage must be observed in all circumstances - the negative thermal coefficient of the PV panels must be taken into account! 